.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56
Brakes - Anti-Lock Brakes/Traction Control
Sheet
021 of 104
V05CM(AU)_12PSHT021
MY2005 VZ COMMERCIALS
F.B.H
B.W.H B.W.H
F.B.H F.B.H
F.B.H
F.B.H F.B.HF.B.H
F.B.H
F.B.H
F.B.H
F.B.H
F.B.HF.B.H F.B.H
Note:-
885
X129080.23
F.B.HF.B.H
B.W.H
B.W.H
RD/YE
YE
885
1440
WH
872
YE
873
072.16
B76
Sensor Asm
RR Whl Spd
_LT
GY
_LT
BU
883
X100
Frt Whl Spd
Sensor Asm
_RTB52
B52
Sensor Asm
Frt Whl Spd
1337
GY/BK
X20012
X20011
PU
884
14 X200
X20013
RR Whl Spd
Sensor Asm
B76 _RT
882
882
BK
BN
830
BK
235 1018 2820
20
Cont
Elek Brk & Tract
Module Asm
A37
B1
Accelerometer A
Veh Latl
X1 2X1 1 X1 3
BU/RD
RD
833
1045
YERD
839
PU
884 1338
L-GN/BK
542
716
BU
A84005.23
RD
BU
883
075.06 X100
HOT IN ACCY OR RUN HOT AT ALL TIMES HOT IN RUN OR START
Traction control cannot be
manually switched off, traction
control does not use throttle
intervention, traction is controlled
by brake intervention.
Low traction is still indicated
by the main LCD display in the
instrument cluster P3.
BX1 AX1BX1 X1 A BX1 X1 A X1 B AX1
RET SIGRET SIGRET SIGRET SIG
SIG_HISIG_LO V_REF
D3
D2D1
C1
M
VALVE
RELAY
A37 - V8 AWD
MOTOR
RELAY
X1 6
STP_LMP_FD
X1
F.B.H
086.46
X157
BK/OG
350
12
PWR_GND
X1
RTFR
WS_HI
4X1
RTFR
WS_LO
X1
RTRR
WS_HI
1X1
RTRR
WS_LO
2X1 X1
SIG_HI
X1
SIG_LO
X1 14
IG_2
X1 25
CLASS2_SER_DAT
X1
IG_1
8
5V_REF
X1
LTFR
WS_HI
X1
LTFR
WS_LO
21X1
LTRR
WS_HI
22X1
LTRR
WS_LO
X1 13
BATT1+
IGNITION
FR_LT_IN
FR-LT_OUT
FR_RT_IN
FR_RT_OUT
RR_LT_IN
RR_LT_OUT
RR_RT_IN
RR_RT_OUT
USV1
USV2
ASV1
ASV2
STOP LAMP FEED
GND MONITORING
CLASS 2 SERDAT
VR MONITORING
MTR MONITORING
MR MONITORING
F.B.H
X157
085.09
15
150
BK
X1
GND
S220058.28
F.B.H
F.B.H
F.B.H
1337
GY/BK
2021 19
B1
Accelerometer A
Veh Latl
X1 2X1 1 X1 3
1338
L-GN/BK
716
BU
SIG_HISIG_LO V_REF
X1X1 X1
RD/YE
X100075.06
_LTB52
Sensor Asm
Frt Whl Spd
RET
BX1
SIG
AX1
1440
F.B.H
S220
058.28
X20011
20
F.B.H
BU/RD
080.23 X129
X1 29
RTRR_WS_HI
X1 8
RTRR_WS_LO
30X1
STP_LP_FD
X1 28
IG
X1 5
LTFR_WS_HI
X1 26
LTFR_WS_LO
X1 7
LTRR_WS_HI
X1 6
LTRR_WS_LO
X1 1
PWR_GND
X1 10
RTFR_WS_HI
X1 9
RTFR_WS_LO
X1 2
BATT+1
X1 3
BATT+2
X1 35
CAN_H1
X1 45
CAN_H2
X1 14
CAN_L1
X1 25
CAN_L2
X1 11
DEN
GND
4X1
884
A116
Module Asm
Tract Cont
X20014
PU
B.W.H
BU
883
B.W.H
872
WH
F.B.H
830
GY
F.B.H
873
BN
F.B.H
X20013
X157
085.09
013.08 A43
2500
Frt Whl Spd
Sensor Asm
B52 _RT
X1 B
RET
X1 A
SIG 086.37 X157
BN/BK
F.B.H
020.25 A112
F.B.H
BK
F.B.H
839
RD
882
12 X200
F.B.H
883
BU
RR Whl Spd
Sensor Asm
B76 _RT
X1 B
RET
X1 A
SIG
RR Whl Spd
Sensor Asm
B76 _LT
X1 B
RET
X1 A
SIG
25012500
F.B.H
BN/BK
F.B.H
BN
A43013.06
BU/BK
020.22 A112
799
F.B.H
BK
B.W.H
882
YE
B.W.H
885
071.42 X40
542
F.B.H
RD
RD
F.B.H
833
072.16 X100
F.B.H
YE
884
F.B.H
PU
885
2501
BN
F.B.H
350
BK
F.B.H
150
BK/OG
F.B.H
HOT IN ACCY OR RUN
HOT AT ALL TIMES
HOT AT ALL TIMES
.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56
Brakes/Traction - Anti Lock Brakes & Traction Control
Sheet
022 of 104
V05CM _12PSHT022(AU)
MY2005 VZ COMMERCIALS
SIG_HISIG_LO 5V_REF
A116 - V6 AWD
.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56
Brakes/Traction - Anti-Lock Brakes & Traction Control
Sheet
023 of 104
V05CM _12PSHT023(AU)
MY2005 VZ COMMERCIALS
RETURN
M
SUPPLY
RELAY
PUMP
MOTOR
RELAY
PUMP
MOTOR
ACTUATION
VALVE
RELAY
A38-V6
A112020.21
BN
BN/BK
F.B.H
2501
F.B.H
2500
BN/BK
2501
F.B.H
BN
2500
F.B.H
013.06 A43 _HFV6
013.08 _HFV6A43
F.B.H
1440
075.06 X100
RD/YE
058.28 S220
X40091.42
799
F.B.H
542
X100072.16X129080.23
BU/BK
F.B.H
20
RDRD
839
F.B.H
BU/RD
F.B.H
BK
F.B.H
882
PU
F.B.H
884
BU
883
F.B.H
086.46 085.09 X157
YE
F.B.H
885
F.B.H
BK/OG
150
F.B.H
BK
X157
X20014
350
13X200
B76 _RT
X1 B
RET
X1 A
SIG
X1 A
SIG
RR Whl Spd
Sensor Asm
B76 _LT
X1 B
RET
X1 A
SIG
RR Whl Spd
Sensor Asm
Frt Whl Spd
RET
BX1
SIG
AX1
Frt Whl Spd
Sensor Asm
B52 _RT
X1 B
RET
X200 11
_LTB52
Sensor Asm
12 X200
882
B.W.H
BK
B.W.H
PU
B.W.H
883
BU
885
B.W.H
YE
884
F.B.H
RD
872
F.B.H
WH
830
F.B.H
BN
833
RTRR_WS_LO
X1 20
STP_LP_FD
873
F.B.H
GY
LTFR_WS_HI
X1 16
LTFR_WS_LO
X1 7
LTRR_WS_HI
X1 17
LTRR_WS_LO
X1 1
PWR_GND
X1 10
RTFR_WS_HI
X1 9
RTFR_WS_LO
X1 19
RTRR_WS_HI
X1 8
BATT+2
X1 25
CAN_H1
X1 26
CAN_H2
X1 14
CAN_L1
X1 15
CAN_L2
X1 11
DEN
GND
4X1
X1 18
IG
X1 5
A38_V6
Module Asm
Elek Brk Cont
X1 2
BATT+1
X1 3
020.23 A112
HOT IN ACCY OR RUN HOT AT ALL TIMES HOT AT ALL TIMES
FR_LT_IN
FR_LT_OUT
FR_RT_IN
FR_RT_OUT
RR_LT_IN
RR_LT_OUT
RR_RT_IN
RR_RT_OUT
OIL SUPPLY
BACK PRESS
062.45 P3
121
BN/RD
F.B.H
X1 30
ENGINEERING ONLY
.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56
Brakes/Traction - Traction Control & Anti-Lock Brakes
Sheet
024 of 104
V05CM _12PSHT024(AU)
MY2005 VZ COMMERCIALS
RETURN M
SUPPLY
RELAY
PUMP
MOTOR
RELAY
PUMP
MOTOR
ACTUATION
VALVE
RELAY
A37-V8
S73
WHEN CONNECTOR A37 IS UNPLUGED
20
F.B.H
BU/RD
TELL TALE LAMPS WILL GO OUT ONCE CONNECTOR IS RE-INSERTED
TELL TALE LAMPS TO COME ON (P3)
NOTE:-
FROM THE A.B.S MODULE PINS 19,20,21 WILL
SHORT CAUSING THE A.B.S OFF & LOW TRACTION
NOTE:- TRACTION CONTROL ON MANUAL
TRANSMISSION HAS SWITCH S73
CONNECTING DIRECTLY TO F.B.H
CONNECTOR X301 F.B.H BECOMES
S73 CONNECTOR
32
T.S.H
BN/WH
5 X301
OG/WH
Frt Whl Spd
Sensor Asm
B52 _RT
X1 B
RET
X1 A
SIG
F.B.H
463
X20014
882
B.W.H
BK
833
F.B.H
RD
31
TCSW
X1 11
UART_SCD
F.B.H
839
RD
PWR_GND
16X1 5
RTFR_WS_HI
X1 4
RTFR_WS_LO
X1 2
RTRR_WS_HI
X1 1
RTRR_WS_LO
SPK_RETARD
28X1
STP_LMP_FD
14X1X1
TACH
30
X1
X1 X1 20
LO_TRAC_WRN_LP
X1 7
LTFR_WS_HI
X1 6
LTFR_WS_LO
X1 9
LTRR_WS_HI
X1 8
LTRR_WS_LO
X1 27
MMI
X1 13
MMR
X1 A37 _V8
Module Asm
Elek Brk & Tract
Cont
BATT1+
17X1
BATT2+
18X1
DEN
12X1
GND
19X1
15
IG
BK
230
T.S.H
GY
072.16 X100
884
F.B.H
PU
882
F.B.H
X20625
F.B.H
GN/WH
F.B.H
464
BK/WH
542
F.B.H
RD
1061
X2 53
SPK_RETARD
150
F.B.H
BK
F.B.H
1687
GY/BK
A84
005.35
Module Asm
Pwrt Cont
873
F.B.H
GY
062.46 P3
P. T. H
BN
121
103.38 A15
12
X40091.42
11
X200
830
F.B.H
BN
X200
X2 5
MMI
T.S.H
1571
RD/WH
F.B.H
BU/BK
Pwrt Cont
Module Asm
005.51
A84
MMR
13X1
RR Whl Spd
Sensor Asm
B76 _RT
X1 B
RET
X1 A
SIG
799
S22_V8019.50
121
BN/RD
YE
T.S.H
151
BK/GN
F.B.H
X1
SIG
AX1
X157
086.46
885
F.B.H
RD/WH
085.09 X157
_LTB52
Sensor Asm
Frt Whl Spd
RET
B
F.B.H
542
RD
F.B.H
1571
BN/RD
542
F.B.H
RD
F.B.H
121 058.28 S220
13X200
3X1
884
B.W.H
PU
Elek Tract Cont
Switch Asm
S73
5X1
GND
ILL_HI
2X1
ILL_LO
6X1
SIG
A15102.14
080.23 X129
A84005.38
B.W.H
883
BU
F.B.H
WH
885
B.W.H
YE
F.B.H
883
BU
872
F.B.H
BN/RD
350
F.B.H
BK/OG
RR Whl Spd
Sensor Asm
B76 _LT
X1 B
RET
X1 A
SIG
121
078.09 X129
HOT AT ALL TIMES HOT IN ACCY OR RUN
HOT WITH PARK LAMPS ON
FR_LT_IN
FR_LT_OUT
FR_RT_IN
FR_RT_OUT
RR_LT_IN
RR_LT_OUT
RR_RT_IN
RR_RT_OUT
OIL SUPPLY
BACK PRESS